A steel pipeline, 2-in, schedule 40 pipe, contains saturated steam at 121.1C. The line is covered with
Fantastic news! We've Found the answer you've been seeking!
Question:
A steel pipeline, 2-in, schedule 40 pipe, contains saturated steam at 121.1°C. The line is covered with 25.4 mm of insulation. Assuming that the inside surface temperature of the metal wall is at 121.1°C and the outer surface of the insulation is at 26.7°C, calculate the heat loss for 30.5 m of pipe. Also, calculate the kg of steam condensed per hour in the pipe due to the heat loss. The average for steel from Appendix A.3 is 45 W/m, K and the k for the insulations is 0.182.