Question: A large vertical finished (inside) shaft diameter of 9.75mis required for hoisting capacity in a planned high volume underground oil shale mine. An aquifer is

A large vertical finished (inside) shaft diameter of 9.75mis required for hoisting capacity in a planned high volume underground oil shale mine. An aquifer is encountered at a depth of 387 m where the water pressure is 1.66 MPa.

(a) Determine the thickness of a concrete liner needed for a liner safety factor of 2.5 when the concrete compressive strength (Co) is 24.2 MPa, Young’s modulus is 38.62GPa Poisson’s ratio is 0.27. Explain, defend your answer.

(b) If changes in the inside diameter of the shaft are monitored for safety, what “reading” in cm would indicate impending failure of the liner?

Step by Step Solution

3.27 Rating (168 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Given Large vertical concrete liner shaft D975 m depth387m Pw 166 MPa Conc... View full answer