Question: A sharp-edged orifice is used to measure the flow of air in a pipe. The pipe diameter is 100 mm and the diameter of the
A sharp-edged orifice is used to measure the flow of air in a pipe. The pipe diameter is 100 mm and the diameter of the orifice is 25 mm. Upstream of the orifice, the absolute pressure is 150 kPa and the temperature is 35°C. The pressure drop across the orifice is15 kPa, and the coefficient of discharge is 0.62. Determine the mass flow rate in the pipeline.
Step by Step Solution
3.47 Rating (157 Votes )
There are 3 Steps involved in it
ATT K1AP 30815 x 04 15 14 150 88 K 3 V R... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
774-P-T-F-L (1800).docx