Copper fins with a thickness of 1.0 mm are installed on a 2.5-cm-diameter tube. The length of

Question:

Copper fins with a thickness of 1.0 mm are installed on a 2.5-cm-diameter tube. The length of each fin is 12 mm. The tube temperature is 275ºC and the fins are exposed to air at 35ºC with a convection heat-transfer coefficient of 120 W/m2 ∙ ºC. Calculate the heat lost by each fin.