A diffuser has air entering at 100 kPa, 300 K, with a velocity of 200 m/s. The

Question:

A diffuser has air entering at 100 kPa, 300 K, with a velocity of 200 m/s. The inlet cross-sectional area of the diffuser is 100 mm2. At the exit, the area is 860 mm2, and the exit velocity is 20 m/s. Determine the exit pressure and temperature of the air.