Find the flows and fluxes of exergy in the condenser of Problem 11.32. Use those to determine
Question:
Problem 11.32
A refrigerator in a laboratory uses R-22 as the working substance. The high pressure is 1200 kPa, the low pressure is 201 kPa, and the compressor is reversible. It should remove 500 W from a specimen currently at –20°C (not equal to T in the cycle) that is inside the refrigerated space. Find the cycle COP and the electrical power required.
Fantastic news! We've Found the answer you've been seeking!
Step by Step Answer:
Related Book For
Fundamentals of Thermodynamics
ISBN: 978-0471152323
6th edition
Authors: Richard E. Sonntag, Claus Borgnakke, Gordon J. Van Wylen
Question Posted: