Meter readings for a three-phase wye-connected alternator supplying power to a motor indicate that the line voltages

Question:

Meter readings for a three-phase wye-connected alternator supplying power to a motor indicate that the line voltages are 330 V, the line currents are 8.4 A, and the total line power is 4.5 kW. Find:
(a) The load in VA
(b) The load pf
(c) The phase current
(d) The phase voltage