A network for a process plant is shown in Fig P19.7. (a) Calculate the energy targets for
Question:
A network for a process plant is shown in Fig P19.7.
(a) Calculate the energy targets for \(\Delta T_{\min }=10{ }^{\circ} \mathrm{C}\) and show a design that achieves these targets.
(b) Explain why the existing network does not achieve the energy targets.
[
(a) \(Q_{\mathrm{C}_{\text {min }}}=190 \mathrm{~kW} ; Q_{\mathrm{H}_{\text {min }}}=90 \mathrm{~kW}\);
(b) there is transfer across the pinch]