Question: A reducer connects a standard 6-in Schedule 40 pipe to a 3-in Schedule 40 pipe. The walls of the conical reducer are tapered at an
A reducer connects a standard 6-in Schedule 40 pipe to a 3-in Schedule 40 pipe. The walls of the conical reducer are tapered at an included angle of 40. The flow rate of water is 500 gal/min and the pressure ahead of the reducer is 125 psig. Considering the energy loss in the reducer, calculate the force exerted on the reducer by the water.
Step by Step Solution
3.31 Rating (169 Votes )
There are 3 Steps involved in it
From Section 108 Q 500 galmin x 1114 fts... View full answer