The specification for of a sieve plate column is given below. Make a preliminary mechanical design for
Question:
The specification for of a sieve plate column is given below. Make a preliminary mechanical design for the column. Your design should include:
(a) Column wall thickness.
(b) Selection and sizing of vessel heads.
(c) The nozzles and flanges (use standard flanges).
(d) Column supporting skirt. You need not design the plates or plate supports.
You should consider the following design loads:
(a) Internal pressure.
(b) Wind loading.
(c) Dead weight of vessel and contents (vessel full of water).
There will be no significant loading from piping and external equipment. Earthquake loading need not be considered.
Column specification:
Length of cylindrical section 37mInternal diameter 1.5mHeads, standard ellipsoidal 50 sieve plates Nozzles: feed, at mid-point, 50mm inside diameter, vapor out, 0.7m below top of cylindrical section, 250mm inside diameter bottom product, center of vessel head, 50mm inside diameter reflux return, 1.0m below top of cylindrical section, 50mm inside diameter Two 0.6m diameter access ports (manholes) situated 1.0m above the bottom and 1.5m below the top of the column Support skirt height 2.5m. Access ladder with platforms Insulation, mineral wool, 50mm thick Materials of construction: vessel stainless steel, Un stabilized (304) nozzles as vessel skirt carbon steel, silicon killed Design pressure 1200kN/m2. Design temperature 150°C. Corrosion allowance 2mm. Make a dimensioned sketch of your design and fill out the column specification sheet given in Appendix G.
Step by Step Answer:
Chemical Engineering Design
ISBN: 9780081025994
6th Edition
Authors: Ray Sinnott, R.K. Sinnott, Sinnott Gavin Towler