The glass pipe system shown below has a liquid flowing in it at an unknown rate. The

Question:

The glass pipe system shown below has a liquid flowing in it at an unknown rate. The liquid is very corrosive and flow meters are correspondingly very expensive. Instead you propose to your boss to add a fluorescent dye via a small pump and to deliver 1.00 g/s of this tracer and activate it by UV light. By monitoring the dye fluorescence downstream, you determine its concentration is 0.050 wt. %. What is the unknown flow rate in kg/hr? (This is a useful method of indirectly measuring flows.)

Trace Concentration UV Lamp 0.050% by Mass W kg/hr Glass Pipe Tracer, 1.00 g/s

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Exploring Engineering An Introduction to Engineering and Design

ISBN: 978-0123747235

2nd edition

Authors: Philip Kosky, George Wise, Robert Balmer, William Keat

Question Posted: