For the pump and piping system of Prob. 1443, plot required pump head H required (m of

Question:

For the pump and piping system of Prob. 14–43, plot required pump head Hrequired (m of water column) as a function of volume flow rate V̇(Lpm). On the same plot, compare available pump head Havailable versus V̇, and mark the operating point. Discuss.


Data from Problem 14–43

A water pump is used to pump water from one large reservoir to another large reservoir that is at a higher elevation. The free surfaces of both reservoirs are exposed to atmospheric pressure, as sketched in Fig. P14–43. The dimensions and minor loss coefficients are provided in the figure. The pump’s performance is approximated by the expression Havailable = H0 – aV̇2, where shutoff head H0 = 24.4 m of water column, coefficient a = 0.0678 m/Lpm2, available pump head Havailable is in units of meters of water column, and capacity V̇ is in units of liters per minute (Lpm). Estimate the capacity delivered by the pump.


Data from FIGURE P14–43

22- 22-21 7.85 m (elevation difference) D = 2.03 cm (pipe diameter) KL. , entrance = 0.50 (pipe entrance) KL,

Step by Step Answer:

Related Book For  book-img-for-question
Question Posted: