In a manufacturing facility, 2-in-diameter brass balls (k = 64.1 Btu/h·ft·°F, Ï = 532 lbm/ft 3 ,

Question:

In a manufacturing facility, 2-in-diameter brass balls (k = 64.1 Btu/h·ft·°F, ρ = 532 lbm/ft3, and cp= 0.092 Btu/lbm·°F) initially at 250°F are quenched in a water bath at 120°F for a period of 2 min at a rate of 120 balls per minute. If the convection heat transfer coefficient is 42 Btu/h·ft2·°F, determine

(a) The temperature of the balls after quenching

(b) The rate at which heat needs to be removed from the water in order to keep its temperature constant at 120°F.

Brass balls 250°F 120°F Water bath