Repeat Prob. 2220, assuming a fouling factor R f, i = 0.0005 m 2 K/W on the
Question:
Repeat Prob. 22–20, assuming a fouling factor Rf, i = 0.0005 m2·K/W on the inner surface of the tube.
Repeat Prob.
Water at an average temperature of 110°C and an average velocity of 3.5 m/s flows through a 5-m-long stainless steel tube (k = 14.2 W/m·K) in a boiler. The inner and outer diameters of the tube are Di = 1.0 cm and Do = 1.4 cm, respectively. If the convection heat transfer coefficient at the outer surface of the tube where boiling is taking place is ho = 8400 W/m2·K, determine the overall heat transfer coefficient Ui of this boiler based on the inner surface area of the tube.