Question: A 20 m long bored concrete pile having a diameter of 350 mm is load tested, and the data are given below: Also given: E
A 20 m long bored concrete pile having a diameter of 350 mm is load tested, and the data are given below:

Also given: Econcrete = 25 × 103 MN/m2.
a. Estimate the allowable pile load using Davisson’s (1973) method, with FS = 2.5.
b. At the maximum load of 1250 kN, what are the total and net settlements?
Load (kN) 0 250 500 750 1000 1250 1000 750 500 250 Settlement 0 2.0 5.0 8.2 15.0 39.6 39.5 38.2 37.5 36.1 35.5 (mm)
Step by Step Solution
3.46 Rating (169 Votes )
There are 3 Steps involved in it
By Davissons method ultimate load can be determine from the load settlement curve According to this ... View full answer
Get step-by-step solutions from verified subject matter experts