Estimate the rate of heat loss per unit length from a 5-cm ID, 6-cm OD steel pipe

Question:

Estimate the rate of heat loss per unit length from a 5-cm ID, 6-cm OD steel pipe covered with high temperature insulation having a thermal conductivity of 0.11 W/(m K) and a thickness of 1.2 cm. Steam flows in the pipe. It has a quality of 99% and is at 150ºC. The unit thermal resistance at the inner wall is 0.0026 (m2 K)/W the heat transfer coefficient at the outer surface is 17 W/(m2 K) and the ambient temperature is 16ºC.

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Principles Of Heat Transfer

ISBN: 9781305387102

8th Edition

Authors: Frank Kreith, Raj M. Manglik, Mark S. Bohn

Question Posted: