1 Approved Answer
A 6 pole DC generator has a flux per pole of 30 mWb. The armature has 536 conductors connected as lap winding. The machine runs
A 6 pole DC generator has a flux per pole of 30 mWb. The armature has 536 conductors connected as lap winding. The machine runs at 1050 rpm, and it delivers a rated armature current of 225A to a load connected to its terminals. Calculate
(a). Generated voltage E a
(b). Electromagnetic torque T e
(c). Power developed, P dev , by the armature
Step by Step Solution
★★★★★
3.49 Rating (159 Votes )
There are 3 Steps involved in it
Step: 1
a Given Data P 6 30 m N 10...Get Instant Access to Expert-Tailored Solutions