1625 In Figure P1625, the voltage across the two loads is jVL j = 4:8 kV rms....

Question:

16–25 In Figure P16–25, the voltage across the two loads is jVL j = 4:8 kV ðrmsÞ. The load Z1 draws an average power of 15 kW at a lagging power factor of 0:8. The load Z2 draws an apparent power of 12 kVA at a lagging power factor of 0:85. The line has an impedance of ZW = 9 + j50 Ω=wire.

Find the apparent power produced by the source and the rms value of the source voltage