For Problem 8.14, calculate the real and reactive power delivered to the three-phase load. Data From Problem
Question:
For Problem 8.14, calculate the real and reactive power delivered to the three-phase load.
Data From Problem 8.14:-
The voltages given in Problem 8.10 are applied to a balanced-Y load consisting of \((12+j 16)\) ohms per phase. The load neutral is solidly grounded. Draw the sequence networks and calculate \(I_{0}, I_{1}\), and \(I_{2}\), the sequence components of the line currents. Then calculate the line currents \(I_{a}, I_{b}\), and \(I_{c}\).
Data From Problem 8.10:-
Given the line-to-ground voltages \(V_{a g}=280 / 0^{\circ}, V_{b g}=250 \angle-110^{\circ}\), and \(V_{c g}=290 / 130^{\circ}\) volts, calculate (a) the sequence components of the line-to-ground voltages, denoted \(V_{\mathrm{L} g 0}, V_{\mathrm{L} g 1}\), and \(V_{\mathrm{L} g 2}\); (b) line-to-line voltages \(V_{a b}, V_{b c}\), and \(V_{c a}\); and (c) sequence components of the line-to-line voltages \(V_{\mathrm{LL} 0}, V_{\mathrm{LL} 1}\), and \(V_{\mathrm{LL} 2}\). Also, verify the following general relation: \(V_{\mathrm{LL} 0}=0, V_{\mathrm{LL} 1}=\sqrt{3} V_{\mathrm{L} g 1} /+30^{\circ}\), and \(V_{\mathrm{LL} 2}=\sqrt{3} V_{\mathrm{L} g 2} /-30^{\circ}\) volts.
Step by Step Answer:
Power System Analysis And Design
ISBN: 9781111425777
5th Edition
Authors: J Duncan Glover, Mulukutla S Sarma, Thomas Overbye