Air at 2 a t m 2 a t m and 500 K 500

Question:

Air at 2 atm and 500 K with a velocity of U=20 m/s flows across a compact heat exchanger matrix having surface type I1.32-0737-S-R. The length of the matrix is 0.8 m. Calculate the heat transfer coefficient and the frictional pressure drop. Use the following properties of air at 500 K and 2 atm:ρ=1.41 kg/m3;Cp=1030 J/kgK;μ=2.69×105 kg/ms;Pr=0.718.

Air at 2 atm and 500 K with a velocity of U=20 m/s flows across a compact heat exchanger matrix having surface type 9.29-0.737-S-R. Calculate the heat transfer coefficient and the frictional pressure drop. The length of the matrix is 0.8 m.

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Design And Analysis Of Thermal Systems

ISBN: 9780367502546

1st Edition

Authors: Malay Kumar Das, Pradipta K. Panigrahi

Question Posted: