For the three-phase power system of Fig. 1.10, the following specifications have been given. Determine the voltage

Question:

For the three-phase power system of Fig. 1.10, the following specifications have been given. Determine the voltage drop of the line in percent:

Line : \(\mathbf{Z}=(10+j 40) \Omega /\) phase Load : \(V=100 \mathrm{kV}, S=50 M V A, P F=0.8\) Lagging

1) \(8 \%\)

2) \(16 \%\)

3) \(19 \%\)

4) \(24 \%\)