Exhaust gas from a power plant passes through a 15- by 20-ft rectangular duct at an average
Question:
Exhaust gas from a power plant passes through a 15- by 20-ft rectangular duct at an average velocity of 50 ft/s. The total length of duct is 250 ft, and there are two 90° bends. The gas is at 180°F and about 1 atm, and the properties are similar to those of air. Calculate the pressure drop in the duct and the power required to overcome pressure losses.