Question: A vertical array of circuit boards is immersed in quiescent ambient air at T = 17C. Although the components protrude from their substrates, it
A vertical array of circuit boards is immersed in quiescent ambient air at T∞ = 17°C. Although the components protrude from their substrates, it is reasonable, as a first approximation, to assume flat plates with uniform surface heat flux q;. Consider boards of length and width L = W = 0.4 m and spacing S = 25 mm. If the maximum allowable board temperature is 77°C, what is the maximum allowable power dissipation per board?
T5L Circuit boards L.
Step by Step Solution
3.36 Rating (165 Votes )
There are 3 Steps involved in it
KNOWN Length width and spacing of vertical circuit boards Maximum allowable board ... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
8-E-M-E-H-M-T (895).docx
120 KBs Word File