Question: When operated at rated voltage and frequency, a three-phase squirrel-cage induction motor (of the design classification known as a high-slip motor) delivers full load at
When operated at rated voltage and frequency, a three-phase squirrel-cage induction motor (of the design classification known as a high-slip motor) delivers full load at a slip of 8.7 percent and develops a maximum torque of 230 percent of full load at a slip of 55 percent. Neglect core and rotational losses and assume that the rotor resistance and inductance remain constant, independent of slip. Determine the torque at starting, with rated voltage and frequency, in per unit based upon its full-load value.
Step by Step Solution
3.28 Rating (172 Votes )
There are 3 Steps involved in it
Given Tmax 23T 8maxT 055 and sa 0087 start by taking the ratio of Eqs 636 and 633 Tmax ... View full answer