Question: A 550-kVA, 60-Hz transformer with a 13.8-kV primary winding draws 4.93 A and 3420 W at no load, rated voltage and frequency. Another transformer has
A 550-kVA, 60-Hz transformer with a 13.8-kV primary winding draws 4.93 A and 3420 W at no load, rated voltage and frequency. Another transformer has a core with all its linear dimensions ~ times as large as the corresponding dimensions of the first transformer. The core material and lamination thickness are the same in both transformers. If the primary windings of both transformers have the same number of turns, what no-load current and power will the second transformer draw with 27.6 kV at 60 Hz impressed on its primary?
Step by Step Solution
3.48 Rating (165 Votes )
There are 3 Steps involved in it
The core length of the second transformer is is 2 times that o... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
20-E-E-E-M (49).docx