Question: Air in a rigid 1 m3 box is at 300 K, 200 kPa. It is heated to 600 K by heat transfer from a reversible
Air in a rigid 1 m3 box is at 300 K, 200 kPa. It is heated to 600 K by heat transfer from a reversible heat pump that receives energy from the ambient at 300 K besides the work input. Use constant specific heat at 300 K. Since the coefficient of performance changes write dQ = mair Cv dT and find dW. Incorporate dW with temperature to find the required heat pump work.
Step by Step Solution
3.53 Rating (156 Votes )
There are 3 Steps involved in it
QH BWQHQLTHT mair PVRT 200 x 1 0287 300 2322 ... View full answer