Figure P19.3 shows a network design using steam, cooling water and some heat recovery. (a) Does this
Question:
Figure P19.3 shows a network design using steam, cooling water and some heat recovery.
(a) Does this design achieve the minimum energy target for \(\Delta T_{\min }=20^{\circ} \mathrm{C}\) ?
(b) If the current network does not achieve the targets, show a network design that does.
[
(a) \(T_{\mathrm{C}_{\text {pinch }}}=150{ }^{\circ} \mathrm{C} ; T_{\mathrm{H}_{\text {pinch }}}=170{ }^{\circ} \mathrm{C} ; Q_{\mathrm{C}}=480 \mathrm{~kW} ; Q_{\mathrm{H}}=380 \mathrm{~kW}\);
(b) \(\left.Q_{\mathrm{C}_{\text {min }}}=360 \mathrm{~kW} ; Q_{\mathrm{H}_{\text {min }}}=260 \mathrm{~kW}\right]\)