In a test of a steam power plant (Fig. P5.1), the measured rate of steam supply was

Question:

In a test of a steam power plant (Fig. P5.1), the measured rate of steam supply was \(7.1 \mathrm{~kg} / \mathrm{s}\) when the net rate of work output was \(5000 \mathrm{~kW}\). The condensate left the condenser as saturated liquid at \(38{ }^{\circ} \mathrm{C}\) and the superheated steam leaving the boiler was at \(10 \mathrm{bar}\) and \(300^{\circ} \mathrm{C}\).

Neglecting the change in state of the feed water in passing through the feed pump, and taking the environment temperature as being equal to the saturation temperature of the

image text in transcribed

condensate in the condenser, calculate the rational efficiency of the work-producing steam circuit (system A). Also calculate the thermal efficiency of the cyclic plant.
[83.3\%;24.3\%]

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Advanced Thermodynamics For Engineers

ISBN: 9780080999838

2nd Edition

Authors: D. E. Winterbone, Ali Turan