Repeat Problem 11.29, but use a 3-in Schedule 40 steel pipe for the discharge line instead of

Question:

Repeat Problem 11.29, but use a 3-in Schedule 40 steel pipe for the discharge line instead of the 2½-in pipe. Compare the power delivered by the pump for the two designs.

Repeat Problem

In a water pollution control project, the polluted water is pumped vertically upward 80 ft and then sprayed into the air to increase the oxygen content in the water and to evaporate volatile materials. The system is sketched in Fig. 11.28. The polluted water has a specific weight of 64.0 lb/ft3 and a dynamic viscosity of 4.0 × 10-5 lbˆ™s/ft2. The flow rate is 0.50 ft3/s. The pressure at the inlet to the pump is 3.50 psi below atmospheric pressure. The total length of discharge pipe is 82 ft. The nozzle has a resistance coefficient of 32.6 based on the velocity head in the discharge pipe. Compute the power delivered by the pump to the fluid. If the pump efficiency is 76 percent, compute the power input to the pump.

Standard elbow 1.30 in diameter Flow 80 ft 24-in Schedule 40 steel pipe 3-in Schedule 40 pipe Pump

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Applied Fluid Mechanics

ISBN: 978-0132558921

7th edition

Authors: Robert L. Mott, Joseph A. Untener

Question Posted: