A house located in Denver, CO, has R-11 walls (1,650 ft 2 ), R-19 ceiling (2,000 ft
Question:
A house located in Denver, CO, has R-11 walls (1,650 ft2), R-19 ceiling
(2,000 ft2), and R-2 windows (200 ft2). Assume that the infiltration/ventilation rate is 0.75 ACH.
a. Estimate the annual fuel energy use and cost savings for retrofitting all the walls of a house to dynamic walls.
b. If we include the effect of heat losses through the foundation, assuming U-effective of Ueff = 0.07 Btu/ft2·hr·°F and an area of 2,000 ft2 for the foundation, do your estimations change significantly.
c. Determine the impact of dynamic walls if the infiltration/ventilation rate is reduced to 0.35 ACH.
Assume that the heating system is a gas furnace with an efficiency of 0.80 and that the fuel cost is $14.0/MMBtu.
Step by Step Answer:
Energy Audit Of Building Systems An Engineering Approach
ISBN: 9780367820466
3rd Edition
Authors: Moncef Krarti