In a food processing plant there is a requirement to heat 50,000 kg/h of town water from

Question:

In a food processing plant there is a requirement to heat 50,000 kg/h of town water from 10 to 70°C. Steam at 2.7 bar is available for heating the water. An existing heat exchanger is available, with the following specification: 

Shell inside diameter 337 mm, E type. 

Baffles 25% cut, set at a spacing of 106 mm. 

Tubes 15 mm inside diameter, 19 mm outside diameter, 4094 mm long. 

Tube pitch 24 mm, triangular. 

Number of tubes 124, arranged in a single pass. 

Would this exchanger be suitable for the specified duty? 

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Chemical Engineering Design

ISBN: 9780128211793

3rd Edition

Authors: Gavin Towler, Ray Sinnott

Question Posted: