Reconsider Prob. 1199. Using EES (or other) software, investigate the effects of the inlet temperature of hot
Question:
Reconsider Prob. 11–99. Using EES (or other) software, investigate the effects of the inlet temperature of hot water and the heat transfer coefficient on the rate of heat transfer and the surface area. Let the inlet temperature vary from 60°C to 120°C and the overall heat transfer coefficient from 750 W/m2 · K to 1250 W/m2 · K. Plot the rate of heat transfer and surface area as functions of the inlet temperature and the heat transfer coefficient, and discuss the results.
Data from problem 99
Cold water (cp = 4180 J/kg · K) leading to a shower enters a thin-walled double-pipe counter-flow heat exchanger at 15°C at a rate of 0.25 kg/s and is heated to 45°C by hot water (cp = 4190 J/kg · K) that enters at 100°C at a rate of 3 kg/s. If the overall heat transfer coefficient is 950 W/m2 · K, determine the rate of heat transfer and the heat transfer surface area of the heat exchanger using the ε-NTU method.
Step by Step Answer:
Heat And Mass Transfer Fundamentals And Applications
ISBN: 9780073398181
5th Edition
Authors: Yunus Cengel, Afshin Ghajar