Question: The specification for the pull strength of a wire that connects an integrated circuit to its frame is 10 g or more. In a sample
The specification for the pull strength of a wire that connects an integrated circuit to its frame is 10 g or more. In a sample of 85 units made with gold wire, 68 met the specification, and in a sample of 120 units made with aluminum wire, 105 met the specification. Find a 95% confidence interval for the difference in the proportions of units that meet the specification between units with gold wire and those with aluminum wire.
Step by Step Solution
3.47 Rating (170 Votes )
There are 3 Steps involved in it
X 68 n X 85 p X 68 185 2 0793103 Y 105 ... View full answer
Get step-by-step solutions from verified subject matter experts
