Problem S10.6. Consider the thermocouple shown in Fig. (10.4). Replace the potentio- meter with a capacitor held

Question:

Problem S10.6. Consider the thermocouple shown in Fig. (10.4). Replace the potentio- meter with a capacitor held at temperature To with wire of metal B attached at points a and

d. Show that

image text in transcribed

where Aada is the potential difference across the capacitor and CA and CB are the differential thermoelectric powers in the two metals (cf. Problem S10.5). Note that in this circuit, there is no electric current.