Nitrogen enters a duct with varying flow area at 400 K, 100 kPa, and a Mach number

Question:

Nitrogen enters a duct with varying flow area at 400 K, 100 kPa, and a Mach number of 0.3. Assuming a steady, isentropic flow, determine the temperature, pressure, and Mach number at a location where the flow area has been reduced by 20 percent.