C Control Chart. An alternative to the U chart is a chart based on the number of
Question:
C Control Chart. An alternative to the U chart is a chart based on the number of defects. The chart has center line at nu, and the control limits are
(a) Verify that the control limits provided are correct.
(b) Apply this chart to the data in Example 15-5.
(c) Will this chart always provide results equivalent to the U chart?
Example 15-5
Printed circuit boards are assembled by a combination of manual assembly and automation. Surface mount technology (SMT) is used to make the mechanical and electrical connections of the components to the board. Every hour, five boards are selected and inspected for process-control purposes. The number of defects in each sample of five boards is noted. Results for 20 samples are shown in Table 15-6.
The center line for the U-chart is
and the upper and lower control limits are
The control chart is plotted in Fig. 15-17. Because LCLis negative, it is set to 0. From the control chart in Fig. 15-17, we see that the process is in control.
Practical Interpretation: Eight defects per group of five circuit boards are too many (about 8 / 5 = 1.6 defects/board), and the process needs improvement. An investigation of the specific types of defects found on the printed circuit board needs to be made. This usually suggests potential avenues for process improvement.
Table 15-16
Figure 15-17
Step by Step Answer:
Applied Statistics And Probability For Engineers
ISBN: 9781118539712
6th Edition
Authors: Douglas C. Montgomery, George C. Runger